Eaton - Tripp Lite SmartOnLine S3MX Series SmartOnline S3MX Series 3-Phase 380/400/415V 100kVA 90kW On-Line Double-Conversion UPS
UPS - 165 A - AC 220/230/240/380/400/415 V - 90 kW - 100000 VA - 3-phase WYE (star) - Ethernet, RS-232 - active PFC
Eaton
S3M100KX
0037332225429
N/A
New
Product Description
Additional Details
What's Included
Main Specifications | |
---|---|
Product Description | Tripp Lite SmartOnLine S3MX Series SmartOnline S3MX Series 3-Phase 380/400/415V 100kVA 90kW On-Line Double-Conversion UPS - UPS - 90 kW - 100000 VA |
Device Type | UPS - active Power Factor Correction (PFC) - external |
Input Wiring | 3-phase WYE (star) |
Input Voltage | AC 220/230/240/380/400/415 V |
Output Voltage | AC 220/230/240/380/400/415 V ± 1% |
Power Capacity | 90 kW / 100000 VA |
Input Connectors | Hardwire |
Output connectors | Hardwire |
Run Time (Up To) | 9 hours at 90% load |
Networking | Ethernet, RS-232 |
Remote Management Protocol | SNMP |
Dimensions (WxDxH) | 22.3 in x 37.2 in x 40 in |
Manufacturer Warranty | 2-year warranty (United States, Canada - 1 year) |
General | |
Device Type | UPS - active Power Factor Correction (PFC) - external |
Expansion / Connectivity | |
Interfaces | 1 x EPO (emergency power off) ¦ 1 x management (RS-232) - 9 pin D-Sub (DB-9) ¦ 1 x LAN ¦ 1 x USB - 4 pin USB Type A ¦ 1 x USB - 5 pin Micro-USB Type B |
Manufacturer Warranty | |
Service & Support | Limited warranty - 2 years ¦ United States: limited warranty - 1 year ¦ Canada: limited warranty - 1 year |
Miscellaneous | |
Cables Included | Serial cable |
Features | Audible alarm, LCD display, LED indicators, cold-start function, cooling fan, double conversion, automatic inverter bypass |
Compliant Standards | RoHS, EN 62040-1:2008, EN 62040-2:2006, IEC 62040-2:2006, IEC 62040-1:2008+A1 |
Networking | |
Remote Management Interface | Ethernet, RS-232 |
Remote Management Protocol | SNMP |
Environmental Parameters | |
Min Operating Temperature | 32 °F |
Max Operating Temperature | 104 °F |
Humidity Range Operating | 5 - 95% (non-condensing) |
Sound Emission | 70 dBA |
Battery | |
Voltage Provided | 240 V |
Power Device | |
UPS Technology | On-line |
Input Voltage | AC 220/230/240/380/400/415 V |
Frequency Provided | 50/60 Hz |
Input Wiring | 3-phase WYE (star) |
Input Connectors | Hardwire |
Power Output Connectors Details | Hardwire |
Output Voltage | AC 220/230/240/380/400/415 V ± 1% - 50/60 Hz |
Max Electric Current | 165 A |
Power Capacity | 90 kW / 100000 VA |
Output Waveform | Sinewave |
Circuit Protection | Circuit breaker |
Efficiency | 98% Eco mode, 94% online mode |
Power Factor (PF) | 0.99 |
Total Harmonic Distortion (THD) | 3 % |
Dimensions & Weight | |
Width | 22.3 in |
Depth | 37.2 in |
Height | 40 in |
Dimensions & Weight (Shipping) | |
Shipping Width | 27.8 in |
Shipping Depth | 44.5 in |
Shipping Height | 46.5 in |